ANESTHESIA MACHINE

Avacs
Powerful features
Ø  Applicable to pediatric and adult.
Ø  Various ventilation modes
Ø  Highly integrated absorber
Ø  The absorber could be automatically heated, to avoid water condensation.
Ø  15inch touch screen
Ø  Touch screen & navigation wheel for simple operation.
Ø  Penlon vaporizer with automatic compensation for temperature, pressure and flow
Ø  Two Vaporizer positions to ensure anesthetic accuracy.
Ø  Proportional valves Technology.
Ø  Close-loop control
Ø  3-level graded And color coded  alarms for different risks
Ø  Electronic flow meter with High accuracy
Ø  Anesthetic gas scavenging system (AGSS) active system (optional)
Ø  Various ventilation modes
Ø  Sophisticated monitoring
Ø  Anesthesia information management system (optional)


Technical data AVACS 50               
STERNMED
Weight (base unit without vaporizers or cylinders)
  108kg
Dimensions (W X H X D)

  1515×1000×690 mm
Power supply
  100-240VAC, 50/60Hz, 6.5A(Max)

Battery (supports ventilator and monitor)
  Minimum 60 minutes

Ventilator E-vent
   Electronically controlled, pneumatically driven
Operating Modes




  VCV, PCV, SIMV(V)+PS, SIMV(P)+PS, Sigh, Cardio pulmonary
  bypass, Spont/CPAP, PRVC, Standby, Manual

Breathing frequency
1-100bpm
Max. Minute volume (MV)
99 l/min (monitoring), 30L/min (setting)
Positive end-expiratory pressure (PEEP)
OFF, 4-30 cm
Inspiration / Expiration ratio (Ti:Te)
4:1-1:9 (increment:0.5)
Pressure limiting (Pmax)
PEEP+5-PEEP+70 cm H2O
Tidal Volume (Vt)

20-1500ml
Inspiratory pause (Tip:Ti)
OFF, 5%-50%
SIMV Inspiratory time (Tinsp)
0.1-10S (increment:0.1S)
Inspiratory pressure (Pinsp)
PEEP+5-PEEP+70 cm H2O
Inspiratory flow (InspFlow)

10-80 L/min
Pressure Support Level (Δ PPS)
5-60 cm H2O
Min. Frequency for and “OFF”   Apnea-Ventilation (Freq.Min.)
1-100 bpm
Trigger
1-15L/Min
Integrated safety functions guarantees












Auto oxygen monitoring, manual oxygen setting a minimum O2concentration of 22%-35% in an O2/N2O mixture. N2O cut-off if O2fresh gas valve is closed or if O2 flow is less than 0.2 L/min. N2O auto cuts off when O2 press lower than 20 psi. in case of electricity failure, manual ventilation or battery supply. Gas delivery and agent delivery are possible. Positive pressure relief valve opens at 70cm H2O, Negative pressure relief valve opens at - 7.5 to - 9 cm H2O

Range of fresh gas flow indicators
0-15 l/min
Total fresh gas flow meter

0-15 L/min with a mixture of O2, N2O and Air
O2 flush

(2.8 bar): min 25 L/min
75 L/min at 41 psi
Vaporizer Mount

Selectatec®
2 position either Drager mount or selectatec
Monitoring






  Continuous  monitoring of aspiratory O2 concentration, breathing 
  frequency, tidal volume, minute volume, mean or plateaupressure, peak 
   airway pressure as well as PEEP.
In addition, all fresh gas flow information is displayed in numbers






Serial interface

   VGA, RS232, RJ45, Debugging
Protocols
No protocols
Data available for export
Alarm history + parameter setting
Volume of CO2 absorber

1.5 liter
Volume of entire compact breathing system
2 liter + bag

PT. MEGA MEDIKA JAYA
Office :
22nd  Floor, Prudential Center, Kota Kasablanka
Jl. Casablanca Raya Kav. 88 JAKARTA 12870-INDONESIA
                                               
Operational Office :
Jl. Tanjung Barat Selatan No. 115 RT 01 RW02     
Kel. Lenteng Agung, Kec. Jagakarsa                        
JAKARTA SELATAN 12610  INDONESIA   

Phone  : 62-21-78830461       
Fax       : 62-21-78830461       
Mobile : 085770226999, 081213786999



Tidak ada komentar:

Posting Komentar