Vento 62
Powerful features
Close-loop control system
Key components are from world leading manufacturers
Proportional valve control technology.
Multiple pressure and volume automatic protective system
Comprehensive alarm system
3-level graded And color coded alarms for different risks
15 inch screen TFT screen
Touch screen & navigation wheel
Setting parameters display is subject to ventilation modes
System log could record 100 settings/alarms.
Keep inspiration & expiration hold for 30s.
Powerful Function with Various ventilation modes
Technical data VENTO 62
|
STERNMED
|
Weight (base unit )
|
45kg
|
Dimensions (H X WX D)
|
1450×590×550 mm
|
Power supply
|
100-240VAC, 50/60Hz, 1A(Max)
|
Battery (Lithium)
|
Minimum 60 minutes
|
Patient type
|
Adult, Pediatric (>5kg)
|
Ventilation modes
|
VCV, PCV, SIMV(V)+PS, SIMV(P)+PS, Sigh,
Spont/CPAP, PRVC, DualPAP, NPPV, Standby, Manual
|
Tidal Volume:
|
20-2000ml
|
Ventilation frequency
|
1-100bpm
|
Inspiration time:
|
0.1-10S (increment:0.1S)
|
FiO2:
|
21% - 100%
|
Flow trigger:
|
0.5-20L/Min
|
Pressure trigger:
|
- 20-0cmH2O
|
Pressure control:
|
5-70 cm H2O
|
Pressure support:
|
0-70 cm H2O
|
Electronic PEEP:
|
0-50 cm H2O (increment: 1cm H2O)
|
Nebulizer:
|
30 minutes
|
Direct access function:
|
100% O2 2 min, Inspiration hold, Expiration hold, Manual, Freeze, Lock
|
Monitoring:
|
Volume: VTI, VTE, MV, MVspont. Pressure: Ppeak, Pmean, Pplat, Pmin, PEEP Freq, fspont, I:E, FiO2, Compliance, Resistance Co2 module (optional): Etco2 Spo2 module(optional): SpO2 , PR
|
Waveform:
|
P-T, F-T, V-T, Optional: SpO2-T, EtCO2-T
|
Loop:
|
P-V, F-V, F-PV Optional: Volume-EtCO2
|
Trend:
|
Peak, FiO2, PEEP, MV, VTE, VTI
|
System Log:
|
500 events (setting and alarm)
|
Alarm:
|
Audio and visual alarms with three levels
Volumes: VTE high/low, MV high/low; Pressure: Paw high/low
O2 supply pressure high/low. Air supply pressure high/low
Apnea, Continuous high airway pressure
Freq high/low FiO, high/low
SpO2 low (optional), EtCO2 high/low (optional)
Power: AC power failure, Low battery power, Exhausted battery failure
|
Communication Interface:
|
VGA, RS232, RJ45, Debugging
|
Screen:
|
15 inch TFT touch screen
|
|
|
| |
PT. MEGA MEDIKA JAYA
Office :
22nd
Floor, Prudential Center, Kota Kasablanka
Jl. Casablanca Raya Kav. 88 JAKARTA
12870-INDONESIA
Operational Office :
Jl. Tanjung Barat Selatan No. 115 RT 01 RW02
Kel. Lenteng Agung, Kec. Jagakarsa
JAKARTA SELATAN 12610 INDONESIA
Phone :
62-21-78830461
Fax :
62-21-78830461
Mobile :
085770226999, 081213786999
Tidak ada komentar:
Posting Komentar