Technical Data M-tex 30
|
Sternmed Digital Mammography System
|
Main unit
|
|
Size
|
1110 (L) x650 (W) x2050 (H) mm
|
Weight
|
< 320Kg
|
C-arm rotating range
|
650~1400mm
|
C-arm rotating angle
|
+185°
|
SID
|
66CM
|
Dual-function pedals
|
2 pay
|
Patient protective mask
|
Removable
|
C-arm rotation angle, position,
oppressive force, oppression thickness be displayed digitally
|
C-arm, two displays on the column
|
Lifting range for compression plate
|
0-270mm (pressure plate to oppression platform height)(manual, electric)
|
Compression plate
|
Conventional compression plate: 24cm x 30cm
|
Conventional compression plate: 18 cm x 24 cm
|
9cm conventional point compression plate 9cm x 9cm
|
Enlarge oppression plate 18cm x 24cm
|
Enlarged compression plate 9cm x 9cm
|
Auxiliary compression plate
|
Small breasts oppression plate
|
Amplification system
|
1.8X magnification platform
1.5X magnification platform
|
Cabinet
|
Column dimensions
(length X width X height)
|
282mmx633mmx830mm
|
Weight
|
≤50Kg
|
Console (Optional)
|
Column dimensions
(length X width X height)
|
784mmX411.5mmX1071mm
|
Weight
|
≤30Kg
|
Tube: IAE
|
Ingredient
|
Molybdenum Target
|
Tube voltage range
|
20~40kV
|
Focus
|
0.1/0.3mm
|
Power
|
4.9kW
|
Anode rate
|
3000/10000rpm(Low / High)
|
Maximum anode dissipation rate
|
750W
|
Heat capacity
|
225kJ(300kHU)
|
Pipe sleeve of thermal
capacity
|
320kJ
|
Tube sets of maximum cooling rate
|
210W
|
Inherent filtration
|
0.5mm Be
|
Angle
|
10°/16°
|
Length
|
320mm
|
Maximum diameter
|
140mm
|
Weight
|
15kg
|
Cooling
|
Nature / air
|
|
High Voltage Generator: Spellman
|
Line Power 1
|
220V±20VAC, single phase, 50/60Hz
|
Line Power 2
|
380V±38VAC, three phase, 50/60Hz
|
Photography voltage
|
20-40KV (step 0.5KV)
|
Photography current
|
10-160mA (sub-file adjustment)
|
Maximum power shooting conditions (@ 0.1S)
|
125 mA @ 40 kVp
|
Nominal power
|
5kW
|
Photography Time
|
5ms-5s
|
Operating Frequency
|
25kHz
|
Maximum KV
|
40KV
|
mAs Range (mAs)
|
0.5mAS-500mAS
|
Control grids
|
There are (vibration grids)
|
AEC
|
There are (automatic AEC, semiautomatic AEC)
|
Collimator: Ralco
|
Maximum X-ray region
|
24X30cm(SID=66cm)
|
Light time
|
<15 s
|
Average illuminance
|
≥160LUX
|
Filtration
|
0.03mmMo,0.025mmRh
|
Adjustment method
|
Automatic
|
Power supply
|
24V DC, 2A
|
Weight
|
3.6Kg
|
Size
|
240 X175 X82MM
|
The shape of the light field
|
≤24X30cm (supports continuous adjustment)
|
HV Cable:
|
Power
|
60kVDC
|
DC voltage
|
90kVDC/15min
|
AC voltage
|
70kV/5min
|
Length
|
10m
|
FPD Detector: Anrad
|
Conversion Screen Type
|
Amorphous selenium
|
Effective pixel region
|
24cmХ30cm
|
Pixel matrix
|
2816X3584
|
Pixel size
|
85um
|
Spatial resolution limit
|
8lp/mm
|
Energy range
|
20~40kVp
|
A / D converter
|
16-bits
|
Acquisition cycle
|
8s (including image processing time was 10s)
|
Data transfer mode
|
Gigabit network transmission
|
Weight
|
3kg
|
Computer System
|
Monitor
|
LCD monitors, 19 inch, 1M color
|
Size
|
440mm*175mm*413mm
|
Volume
|
25L
|
Weight
|
8.5 kg
|
Chipset
|
INTER Q77
|
Processor
|
I5-3470 (VPRO) (CORE I5 3.2G 6M cache)
|
Integrated graphics
|
Integrated graphics
|
Sound Card
|
Integrated High Definition Audio
|
NIC
|
Motherboard integrated Gigabit Ethernet
|
|
|
Independent card
|
PRO/1000 PT Desktop Adapter
|
Memory Specifications
|
DDR3 1333
|
Memory
|
8G DDR3
|
Hard Specifications
|
SATA 7.2K
|
Hard drive capacity
|
500G hard disk partitions: C disk 60GB NTFS format, E disk 20GB FAT32 format, the remaining space forthe D drive NTFS format
|
COM interface
|
COM1
|
Drive bays
|
Interior: 2 * 5.25 1 * 3.5 external: 1 * 3.5
(expandable to 2 * 3.5)
|
Expansion Slots
|
2*PCI 2.3 1*PCIeX1 1*PCIeX16
|
Software
|
Patient Management
|
patient information registration, save, set an appointment, query and other functions
|
Inspection management
|
parameter setting, exposure collection, automatic image processing
|
Image Browser
|
image selection, image processing (crop, zoom, grayscale adjustment, rotate, flip, tag, window layout, etc.)
|
Image post-processing
|
image enhancement, tissue equalization, noise reduction, gradation values of tensile
|
Image output
|
support for laser printer output, support for the laser camera output, DICOM interface and hard
|
Data Management
|
data deletion, statistics, edit, backup and recovery
|
Other features
|
detector calibration procedures, failure error function, Work list
module
|
Packing Information
|
packing size (mm)(L*W*H)
|
Weight 320 KG
|
Column : 2230*1060*1480
|
60
|
Cabinet: 800*490*1035
|
20
|
Accessories :1080*635*730
|
30
|
Compressing devices:
1080*635*730
|
30
|
Environment requirement
|
Work Environment
|
Temp:12°C~37°C
|
Humidity :20%~90% (No condensation)
|
Atmospheric pressure :70kPa~106kPa
|
Storage Environment
|
Temp:5°C~40°C
|
Humidity :20%~90%
|
Atmospheric pressure:70kPa~106kPa
|
| | |